For use in interior applications with high loads or those that require long spans, including beams, columns, floor joists, roof rafters, girts, purlins and similar structural applications.
Popular with architects, Beam 16C has been used as lintels, bearers, roof beams, rafters, curves, columns and portal frames in a number of amazing structures.
Stocked Sizes:
Lengths available in 0.6m increments up to 10.8m.
Grades: I-Built Beam 16 is available Structural Grade in accordance with AS/NZS1328.1-1998.
Location - In wind zones up to and including extra high as defined in NZS 3604:2011 or to a maximum wind design pressure (ULS) of ULS 2.1 kPa. In all exposure zones as defined in NZS 3604:2011.In all Seismic and snow zones. At least 1m from a relevant or notational boundary.
In conjunction with a primary structure that complies with the NZ Building Code or where the designer has established that the existing structure is suitable for the intended building work. In conjunction with timber framing as defined in NZS 3604:2011 or designed in accordance with AS/NZS 1170 (set). As a direct substitute to SG8, SG10, and SG12 (or other equivalent engineered timber products) as referenced in section 8 NZS 3604:2011 or where specifically engineered to NZS 3603:1993 or AS/NZS 1170 (set).
Manufactured in accordance with AS/NZS 1328.1:1998, as referenced in clause 2.3.9, NZS 3604:2011. Holds Bureau Veritas S-Mark Licence No. 2757 [Bureau Veritas, 14/09/2023].
Characteristic properties to AS/NZS 4063 [Griffith University, 11/21]
In accordance with para.1.9, AS/NZS 1604.5:2012, the penetration and retention characteristics meet the specifications outlined in NZS 3640:2003.› Glue-line integrity meets service class 3 in accordance with AS/NZS 1328.1:1998 [Hyne Timber 10/21a,b].
Timber Preservation ABN: 15 109 657 276. Timber treated to Hazard Class H3 (H3.1 for New Zealand) [Cahill Timber, 25/09/2023].
Exposure conditions specified by AS/NZS 1604.1:2021.
Use in accordance with the manufacturer’s safety information.
Formaldehyde emission rate of less than 0.3 mg/L verified through panel testing to AS/NZS 4357.4. Meets Super E0 Emission Class requirements in accordance with AS/NZS 2269.0 [Hyne Timber 10/21a, b]
The product will, if installed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
16C20, 16C24, 16C26, 16C30, 16C33, 16C36, 16C40, 16C46
This product has no warnings associated with it.