Compliance Statement
Scope of Use
FIRESTOP HK-100 is a fire-rated intumescent insert designed for
firestopping electric cable penetrations through fire-rated plasterboard walls
and ceilings, as well as 16 mm PEX pipe penetrations through fire-rated plasterboard
walls. Available in HK-100/14 and HK-100/20, the insert provides a neat, flush
finish and allows cables to be added, removed or repositioned after
installation. FIRESTOP HK-100 has been fire tested in New Zealand at an
accredited laboratory in accordance with AS 1530.4:2014 and AS 4072.1:2005, in
conjunction with FIRESTOP Ultra sealant. It is suitable for single cables and
cable bundles up to 20 mm in diameter, including tested TPS, Fire Alarm and
CAT6 cables.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
Notes
FIRESTOP HK-100 Inserts have been tested to AS1530.4:2014 and AS4702.1:2005.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
FIRESTOP HK-100 Inserts have been tested to AS 1530.4:2014 and AS 4072.1:2005, providing fire resistance ratings (FRR) when applied to fire-rated substrates in accordance with the relevant tested system, tech drawings and product information.
Please refer to below links:
FIRESTOP HK-100 product page
FIRESTOP HK-100 BPIR Sheet