Compliance Statement
                                                                                            
                                                                                            
                                                                                                Scope of Use
                                                                                                BRANZ appraised, flexible synthetic underlay consisting of a micro-porous, water-resistant inner layer laminated to spun-bonded polypropylene layers.  Fire-retardant with a flammability index of ≤5, tested to AS/NZS 1530.2.  Appraised for use up to and including very high wind zones and when installed over a rigid wall underlay for extra high wind zones.  Coloured grey with brand logo printed along roll length.  Available in 1500mm wide x 50m long and 2740mm wide x 36.5m long rolls.Ventia Iron Wall Underlay is suitable for use behind direct fixed and non-direct fixed, absorbent and non-absorbent wall cladding on timber or light steel framed buildings, underlay in accordance with NZBC E2/AS1, Table 23 and NZS 2295, Table 2.4.Ventia Iron Wall Underlay can also be used as an air barrier in unlined walls behind stucco plaster, or as a non-rigid backing material when supported by 75mm galvanized mesh, or as a slip layer over rigid backing, to NZBC E2/AS1.
                                                                                             
                                                                                            
                                                                                            
                                                                                                New Zealand Building Code (NZBC)
                                                                                                The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
                                                                                                - Clause B2 Durability: Performance  B2.3.1(b)
Branz Appraised
 - Clause E2 External moisture: Performance  E2.3.2, E2.3.6
Branz Appraised